Home Company Info Product List Contact Details
Homeproduct Directory

Waste Heat Recovery MISSION WHR-GT

Waste Heat Recovery MISSION WHR-GT
company Haian Sodbos company
Categories Gas Turbine Generators
Update2011-02-28
Original RegionChina
Waste Heat Recovery MISSION WHR-GT

MISSION WHR-GT

________________________________________________________________________________________

General

  • Standard HRSG (heat recovery steam generator/economizer) for installation behind gas turbines
  • Vertical water tube boiler with forced circulation
  • Sturdy design
  • Compact design (small footprint)
  • Easy service and inspection
  • Fully drainable
  • Fast response to load changes
  • Fast start-up time
  • Dry running at full load on gas turbine

Design data

Gas turbine output:10 - 35 MW
Gas turbine fuel type:Natural gas, light oil
Exhaust gas flow:40 - 120 kg/s
Exhaust gas temperature:< 570 C
Steam capacity:10 - 50 t/h
Operating steam pressure:10 - 35 bar
Steam temperature:Saturated - 450 C

Description

MISSION WHR-GT is the latest marine economizer developed by Aalborg Industries and is designed for installation behind a gas turbine.

Waste heat from the gas turbine exhaust gas is used for generating saturated or superheated steam.

The waste heat recovery boiler/economizer is of the forced circulation type. The economizer is fully constructed of high temperature resistant Chrome Molybdenum steel.

DATA SHEET series
Aalborg Industries 2006, (Design data are subject to change without prior notice).

________________

Related material:

  • Download MISSION WHR-GT datasheet
  • Download complete exhaust gas ecomizer product range

Waste Heat Recovery MISSION WHR-GT on sale

Products Showcase

See more products from this supplier.

Do you want to show products of your own company? Join FREE now!

You may also be interested in: